Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 107 of 1411

Provide a list of Outdated Cached References

If a drainage profile uses a cached view rather than a dynamic one, ORD will provide a notification in the bottom right-hand corner that simply says "Cached References are currently displayed. One or more cached references does not match the curre...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add reflect option for DU cells.

Implement a way to minimize the number of cells by allowing reflecting and mirroring of nodes during placement and manipulation.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Show Connected Conduits in Profile

The ability to show the cross-pipes in profile runs right now is by default a user preference. It would be nice if this could just be a standard function or at least set to "True" as a default to be turned off if desired.
over 1 year ago in Drainage and Utilities 0 Future consideration

ORD Drainage - Make item Type Properties available in flex tables.

when adding columns to flex tables we need the ability to add item type properties to the flex tables. similar to how we can create UDX properties and show them on flex tables.
11 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

DU: Node inventory report

Report tool to quickly generate a table similar to the conduit inventory, but for nodes feature types.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 3 Already exists

Connection Region in Bottom of Node

The current connection region of drainage nodes are available for the side faces of node only. The software should allow the connection region of pipe/conduit from the bottom of the node.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD Drainage - Separate CUlverts and Storm Sewer Pipes into Completely Separate Design Windows

Having to click 'Is Culvert' is just one more placve an error can take place in design. Creating spearate design windows for each of these elements will minimize this potential, and will make it easier for reviews as well.
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Add surface to multiple drainage profiles quickly & in batch

I would like to be able to select multiple pipe profiles in the drainage and utilities tab and right click to add a surface to all of them at once. This will save a considerable amount of time - instead of needing to open each profile model indivi...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Civil view Settings (Drainage and utilities) in Personal Preference

Have the Civil preference for drainage and utilities as file setting rather than personal preference. There are times we had to change the settings depends on what we are designing. eg. we want to show connecting conduit if we do drainage, not whe...
about 1 month ago in Drainage and Utilities 0 Needs review

Circular Eccentric Nodes should have the ability to have a rotation point at the center of the structure.

Circular eccentric nodes, like manholes, should have the ability to have a rotation point at the center of the structure and elevation reference at the center of the frame and cover.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration