Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Functional Areas

Showing 109

Toggle Drainage Calculations On or Off

Applicable to OpenRoads Drainage, CivilStorm, and StormCAD Bentley drainage software tries to do too much / it tries to do ALL the calculations, even if you don’t want to. There have been times I have had separate drainage models: one for inlet sp...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

PMM non-linear springs

We would like to ask a PMM non-linear spring for modeling Plastic Hinges for reinforced-concrete Columns. This PMM springs are used for modeling the Moment-Rotation (M-R) behavior for different axial loads (P). The PMM spring should be able to cap...
about 1 year ago in Analytics / OpenBridge Designer 0 Needs review

Openroads IFC Flex table data added to export

Issue: No way to export Flex table data from Openroads to IFC. Impact: This prevents us from meeting client standards for data-rich IFC outputs on infrastructure projects in Europe. Request: Add functionality to export Flex table data to IFC as a ...
about 1 year ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Needs review

Enhancement::Additional Tool for Design of Cross over connection between Tangent & Canted Tracks

I suggest improvements to Bentley OpenRail Designer for handling Cross over connections in the following scenarios: Cross over Between Adjacent Tangent Tracks: Enable a simple geometric connection between two parallel tracks without the use of Geo...
about 1 year ago in OpenRail Designer / Turnouts/Crossings 0 Needs review

Ability to Place a Conduit/Pipe "Without" a Node

Many times, we have conduits/pipes that simply daylight a surface and drain on to the ground or into a pond. Please add the ability to place conduit/pipes "Without" the need of a Node. I understand that we can create a sort of null point/node that...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

provide highlighting or red text for the following note to better stand out when value is non-zero

Enhancement Request to provide highlighting or red text for the following note to better stand out when value is non-zero.
about 1 year ago in OpenBridge Designer / User Interface 0 Needs review

Make Survey Attribution Easier to Import

Currently, ORD cannot process more than two attributes from a survey data file into their own unique attribute column. The workaround is tedious and unintuitive: First, modify the CSV file from the data collector (not good practice to modify a sur...
about 1 year ago in OpenRail Designer / OpenRoads Designer / OpenSite Designer / Survey 0 Needs review

Fiber Mesh Cross Sectional Analysis

Con sider adding fiber-mesh tools for cross section analysis to RMBRIDGE. This allow the use of different materials in the cross section. This is important in seismic analysis for the definition of the Moment-Curvature properties. This feature is ...
about 1 year ago in Analytics / OpenBridge Designer 0 Needs review

Set size for Conduit in the Feature Definition.

Currently we have generic pipes (ie RCP Class III) and on placement, the user defines the size by using the description field. Because of this, I cannot attach an Item Type and explicitly set the Pay Item information. If I can set what the size of...
about 1 year ago in Drainage and Utilities 1 Needs review

Itwin cannot synch .dgndb files using the online connector.

The connector for .dgndb is only available in the desktop synchronizer. Shouldn´t it be available in the online portal?
about 1 year ago in Import/Export / OpenRail ConceptStation / OpenRoads ConceptStation 0 Needs review