Ability to Export Profile Run To Consider Node Length

Currently it is not possible to export the alignment and profile from Profile Run with same station as it considers the nodes in the profile. We can select the conduit and export it, but this would be actual conduit length not the center to center...
9 months ago in Drainage and Utilities / Import/Export / OpenRail Designer / OpenRoads Designer 1 Needs review

Add columns for conduit construction length and constuction slope to flex table

Is there a way to add constructed length and constructed slope to a conduit flex table? I can build annotation for these fields for plan production, but I haven't found these fields to add to a conduit flex table. This would allow for more options...
almost 3 years ago in Drainage and Utilities 0 Already exists

limit the number of Rows in the Elevation-Area Table.

I get close to 40-50 rows of data when I assign a "pond" to a terrian. I only need data every 0.1ft but it is providing much more.
about 2 years ago in Drainage and Utilities 0 Future consideration

Issues with Drainage Prompt to compress database

The prompt for compressing the drainage database needs some work: It really should be removed. Salvaging anything marked for deletion but not compressed isn't really feasible in OpenRoads environment. Do not prompt me twice. It should be assumed t...
9 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 1 Future consideration

ORD SUDA - Single gradient property - False for stormwater and wastewater conduit

Hi, We were wondering if it would be possible to change the single gradient property function for stormwater and wastewater conduit. "Single Gradient - This is always set to true for storm and sanitary conduits. For other types of conduit, it i...
9 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer 2 Future consideration

Add Conduit To Existing Profile Run

It would be very helpful if there was a way to simply Add a Conduit to an existing Profile Run. For example, I have a storm network modeled and a bunch of drawings created by using a Profile Run, but now I needed to add another conduit at the end ...
9 months ago in Drainage and Utilities / Drawing Production / OpenRail Designer / OpenRoads Designer 0 Future consideration

Allow Conduits from different "families" to connect to the same node.

Add support for nodes that accept multiple types of conduit families.
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

DU: Only modelling workflow

When starting a DU, OpenRoads creates a whole DU project inside the file and brings a lot of hidroly/hidraulic properties with it. That's fine if the goal is to run an analysis. But what if I just want to model a whole network and never run it? Di...
over 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Allow spread sections to be read directly from a terrain model or Corridor Model

Geopak Drainage could read a TIN file to establish the cross slopes for spread. This functionality should still existing in Drainage and Utilities by reading corridor models and terrain models. Users should be allowed to define an infinite number ...
over 2 years ago in Drainage and Utilities 1 Already exists

Visualization of Flood Fill based on min and max height values

A function of flood fill a portion of the terrain based on a min height and max height value. It allows a drainage engineer to visually check if a certain flood top water level will flow beyond the project boundary. Is there a way to do this in Op...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration