Drainage and Utilities

Showing 110

External model checking process - by possibly running a report to identify where 3d conduit string lines have been placed - i.e soffit, centre, invert, crown or base, this will ensure all output data of conduits are consistent for construction.

This is useful to enable a) - checks to be carried out, b) - to identify possible conduits that require amending - to align with all others. This will enable consistent and accurate output data to be produced, that can be used to construct from.
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

ORD DU File Recovery Tools

ORD DU File recovery tools would be extremely handy when dealing with support issues. I've had to deal with a support ticket where the file is crashing upon opening several times now, and being able to run some tools outside of ORD would be extrem...
7 months ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Future consideration

Needs ability to set RIM Depression Depth

Needs ability to add RIM Depression Depth with elevation (ground). Currently we can only set the Elevation (RIm) but not any depression value.
almost 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 1 Future consideration

Channels Attach to other nodes besides headwall

If ditches do become channel features, KYTC would need channels to then be able to attach to other node types besides headwalls since we have many conditions and locations where they outlet into inlets of various types.

Ditches be channel features

It would be wonderful if ditches were channel features so that they could be treated as surface features like gutters are to get head on inlet.

Custom Grate Spacing and Sizes

It would be amazing if we could utilize our own grate spacing for calculating the head on inlets. KYTC has several grates that don't quite match with what is in the delivered system, and this may affect the depth of the head on the inlet.

Element Templates Point to Multiple Cells

At KYTC we like to show the vaults of drainage structures, in order to do that S&S drew them for us. ORD does that in 3D, however, we turn the 3D off when producing plans. It would help in the case that we could point to two cells (one that ma...

ORD Drainage - Show actual Tc versus Tc Minimum

Many times a calculated Time of Concentration is less than the minimum used for Intensity. When this occurs in a system of drainage areas (catchments), it helps a designer AND a reviewer to see what the actual Time of Concentration is at a given p...
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Profile Annotation Groups

A lot of our project show multiple profiles in one profile view (EG, Proposed PGL, RT Gutter, LT Gutter, etc.). In MicroStation we set up a specific .ddb file that would plot the text labels in the desired location. We haven’t been successful in c...

limit the number of Rows in the Elevation-Area Table.

I get close to 40-50 rows of data when I assign a "pond" to a terrian. I only need data every 0.1ft but it is providing much more.
12 months ago in Drainage and Utilities 0 Future consideration