Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

Drainage and Utilities

Showing 114

Ditches be channel features

It would be wonderful if ditches were channel features so that they could be treated as surface features like gutters are to get head on inlet.

Custom Grate Spacing and Sizes

It would be amazing if we could utilize our own grate spacing for calculating the head on inlets. KYTC has several grates that don't quite match with what is in the delivered system, and this may affect the depth of the head on the inlet.

Element Templates Point to Multiple Cells

At KYTC we like to show the vaults of drainage structures, in order to do that S&S drew them for us. ORD does that in 3D, however, we turn the 3D off when producing plans. It would help in the case that we could point to two cells (one that ma...

limit the number of Rows in the Elevation-Area Table.

I get close to 40-50 rows of data when I assign a "pond" to a terrian. I only need data every 0.1ft but it is providing much more.
about 1 year ago in Drainage and Utilities 0 Future consideration

Display and Annotate Tap Nodes in Profile Drawing

The feature name (e.g. a number) of the tap node can be labeled in the plan.The tap is visible in the "Engineering Profile".It would be helpful if this could also be displayed and labeled in the profile view/drawing. How it should work: Tap Node i...
about 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Profile Annotation Groups

A lot of our project show multiple profiles in one profile view (EG, Proposed PGL, RT Gutter, LT Gutter, etc.). In MicroStation we set up a specific .ddb file that would plot the text labels in the desired location. We haven’t been successful in c...

Allow Conduits from different "families" to connect to the same node.

Add support for nodes that accept multiple types of conduit families.
about 1 year ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Needs review

Simplfy the Interface - How many "sizes" can there be?

Object Properties - Feature Definition of a pipe is top level, its description is a pick list of diameters (TxDOT), but Utilities Properties has three different locations. This complexity is unnecessary.

Gutter spread - flip side

Why do gutters not have a "side" as spread when drawn appear in the right side.

If no Design Lenghts in Catalog - Ignore or Set Design Inlet Openings to false

I do not see a place to force in a Inlet Catalog to set "Design Inlet Opening" to false, so I would like the software to assume False if lenghts are NOT in the catalog.