When editing points in ITL and applying a feature name override, there should be a pick list of all currently defined name overrides. Right now the only option is to remember what names you have assigned.
OpenRoads Modeling > Terrain > Create > Additionnal Methods > Create Corridor Alternate Surfaces. Add an Toggle on/off option to create a Feature Boundary on each alternate surfaces based on the ends linear.
Select Multiple Annotation Definitions Simultaneously While Building Annotation Group
While building an Annotation Group, Annotation Definitions have to be selected one at a time in a temporary window. Make the definition selection window persistent, and allow multiple definitions to be simultaneously selected for addition to the a...
Ability to lock profile when start stationing changes
Right now (2022 R1) if an alignment with a profile is extended in the start, the profile moves together with the start of the alignment. Two wishes: Possibility to lock the profile elements in their present position. Possibility to move the whole ...
U.S. surveyors traditionally work in Northing & Easting, in that order. When working with Microstation V8i, AND with Inroads loaded, the user could perform precision drafting by using the “NE= “ key-in to enter the exact northing/easting coord...
Productivity enhancements to Corridor Objects dialog
There are currently some things needed to be added to the Corridor Object dialog to help communicate design intent a bit better to users (especially with Parametric Constraints): The lack of information as to the rules linked to Parametric Constra...
Dont reset terrain Feature Definition when changing annotation scale
Since Bentley support told me this is works as designed and to submit an idea (when obviously this should just be fixed, yes FIXED because the way its working now is just wrong!) When you're in the model that contains the terrain, and you change t...
Linear Template - the BSplines warning is not helpful
When you place a Linear Template on a splined element a warning is generated which requires user interaction to dismiss: "Warning: The base geometry selected for this corridor contains B-Spline elements for the horizontal Transitions. Consider rec...
Either add ability for multiple users to be in the same ITL and save the information. At the moment we run a separate ITL for segments of a project which leads to slight differences to similar items. It is cumbersome to use the template library or...
Civil Labels Update Automatically in Files When dgnlib is Updated
Example would be for Pipe lengths. If a label is set to place the "designed" pipe length, but it needs to be changed to constructed pipe length. And that civil label has been used multiple times in multiple sheets. It would be great if when someon...