ORD Drainage - Separate CUlverts and Storm Sewer Pipes into Completely Separate Design Windows
Having to click 'Is Culvert' is just one more placve an error can take place in design. Creating spearate design windows for each of these elements will minimize this potential, and will make it easier for reviews as well.
Allow Plan Annotation>Arc>“Arc Length” property to annotate length for both Arc and Chord Definition curves so that only one text favorite is necessary to annotate curve length if both types of definitions exist in the same alignment.
With this issue we need to be able to create a single Alignment Feature Definition that will be able to annotate both Arc and Chord defined Curves in the same alignment. That single Alignment Feature Definition will have a Length Label “L” and it ...
Add ON/OFF toggle option to Civil Labeler for Arrow Head
Just like you already have the option to toggle on and off a Box Frame or Text Divider around a label and the option to have a leader line or not, we would find it very useful to have the option to toggle ON/OFF an arrowhead.
There is no way to easily measure an area within a cross section.
In ORD when you attempt to measure the graphics within a XS View it appears that you get the surface area of the entire cut or fill volume. As a user, I need the specific end area for the element. Presently you have to trace the element with a mea...
Set Item Types and their attributes in the Template Library
Currently item types and their attributes would need to be programmed into to read a component or selected manually after an element is displayed. If the templates in the template library had the ability to set these selections and values ahead of...
Ability to customize Slopes between points symbology and ruled
When labeling site pavements slopes, the tool only allows for a pre-defined symbology (slope=X.XX% ->) and it`s a simple text.We use a different symbology, basically a arrow cell and a text between the two points.The abillity to customize the l...
Ability to modify 'Rational Method Frequency Adjustment Factor' for a specific catchment or range of catchments.
Currently there is only an option to add Rational Method Frequency Adjustment Factors for the entire storm, which affects all catchments. Our GDOT standards require modification of the factor for only C values less than 0.6.
Inserting the actual profile of reference adjacent profile
This is a missing feature on the Project Profile to Element as it is only accurate when two elements are actually parallel. We need some feature that will instantly copy/insert the profile of the adjacent element which is usually a reference dgn. ...
I would like to have possibility to turn on static grid in geometry profile view. Something like the ability to set the main grid and minor grid intervals in the geometry profile view in the same way like it is done in drawings and sheets and make...