Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 1715 of 1715

Openroads IFC Flex table data added to export

Issue: No way to export Flex table data from Openroads to IFC. Impact: This prevents us from meeting client standards for data-rich IFC outputs on infrastructure projects in Europe. Request: Add functionality to export Flex table data to IFC as a ...
about 1 year ago in Import/Export / OpenRail Designer / OpenRoads Designer / OpenSite Designer 2 Needs review

provide highlighting or red text for the following note to better stand out when value is non-zero

Enhancement Request to provide highlighting or red text for the following note to better stand out when value is non-zero.
about 1 year ago in OpenBridge Designer / User Interface 0 Needs review

Update "Coordinate Grid" tool to allow more options

The "Coordinate Grid" tool needs to be updated to provide more options of the coordinate text placement allowing offsets & rotation etc. There should be, at a minimum, the same amount of control as we had with the InRoads tool "Place Coordinat...
over 2 years ago in Annotation / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Future consideration

Set size for Conduit in the Feature Definition.

Currently we have generic pipes (ie RCP Class III) and on placement, the user defines the size by using the description field. Because of this, I cannot attach an Item Type and explicitly set the Pay Item information. If I can set what the size of...
about 1 year ago in Drainage and Utilities 1 Needs review

Unit Cost

Allow user to pre-set default Unit Cost in Component Quantities for the corridor
about 1 year ago in OpenRail Designer / OpenRoads Designer / Reports 0 Future consideration

Composite Deflection Multipliers

LEAP Concrete defaults PCI Bridge Design Manual Table 8.7.1-1 for the deflection multipliers. However, in the same section, it is indicated that the composite multipliers given in the table are not properly account for the significant effects of a...
about 1 year ago in OpenBridge Designer 0 Future consideration

Allow member groups to start and stop at the same support line in LBS

We are modeling a complex bridge in LBS and the bridge is flared. The flare has required the addition of shorter beams that are not full length to keep the beam spacing on the flared end reasonable. Currently LBS does not allow more than one beam ...
over 2 years ago in Modeling / OpenBridge Designer / OpenBridge Modeler 0 Needs review

Bridge centerline

It will be very helpful if OBM can project the deck centerline along the length of the bridge.
over 2 years ago in OpenBridge Designer / OpenBridge Modeler 0 Future consideration

Flextable Export to Different Custom Excel Styles

Currently, Flextable can only export to csv with all colums. To make as proper report, user need to manually copy/paste the data. If the Flextable or software can export those nodes, conduits and hydrailuc properties, computation results to select...
over 2 years ago in Drainage and Utilities / OpenRail Designer / OpenRoads Designer / OpenSite Designer 0 Already exists

Native ability to import and link excel tables in OpenRoads Designer

Please consider adding a native tool to allow users to import excel files to OpenRoads Designer and be dynamically linked to the original excel file to enhance workflows.
over 2 years ago in  0 Already exists